APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20700 Issued:1991-08-05
Revised:2012-04-20
Style 20700 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG solid or stranded round.
InsulationExtruded ECTFE or ETFE or FEP or PFA or PTFE, TFE, 4 mils min average, 3 mils min at any point.
AssemblyTwo to ten conductors.
ShieldOptional.
JacketExtruded FEP or PFA or PTFE, TFE, 3 mils min average, 2 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseClass 2 wiring of electronic equipment