APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20702 Issued:1991-08-05
Revised:2012-06-25
Style 20702 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor33 AWG - 18 AWG, solid or stranded.
InsulationExtruded Polyester, 7 mils minimum average, 5 mils minimum at any point.
AssemblyTwo to ten conductors. May include mixed AWG sizes. Core may be either flat or round.
CoveringOptional. Extruded Nylon (Polyamide), 3 mils minimum at any point.
ShieldOptional.
JacketExtruded TPE, 25 mils min average, 21 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA. "External interconnection of electronic equipment where the overall length does not exceed 5 ft". or B. "External interconnection of electronic equipment where not routed along walls, floors, or other abuse areas".

UL and the UL Logo are trademarks of UL LLC © 2024