Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 34 AWG - 24 AWG, solid or stranded. |
|
Insulation | Extruded Silicone Polyimide copolymer, 10 mils minimum average thickness, 7.5 mils minimum thickness at any point. See Facing Page for compound details. Insulation may be applied as one single extrusion, or two extrusions consisting of pre-insulated singles laid parallel or twisted together, intermittently or continuously bonded together by a second extrusion forming the flat cable minimum insulation thickness at any point along the intermittently bonded cable shall be 10 mils. |
|
Assembly | Two to 150 conductors. May include mixed gauges. |
|
Shield | Optional. |
|
Covering | Optional. Extruded Silicone Polyimide Copolymer, 5 mils minimum thickness at any point, 80 mils maximum thickness. See Facing Page for compound for details. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|