Rating | 105 deg C, 60 Vac, Horizontal Flame. |
|
Conductor | 42 AWG - 12 AWG, flat or round. If flat conductors, 1.0 - 10.0 mils thickness, 3 - 100 mils wide. |
|
Insulation | (1) PVC, 3.5 mils minimum bonded each side, or (2) 0.4 mil minimum biaxially oriented PETP film bonded each side with 0.5 mil polyester adhesive or (3) 0.8 mil minimum PETP film or flame retardant polyester film and 2.5 mils minimum PVC adhesive on each side of conductors laminated together. 10 mils minimum edge width and 3 mils minimum between conductors. (4) 0.4 mil minimum polyimide film bonded on each side of conductors with 0.4 mil minimum polyester adhesive. Total combined thickness shall be 0.8 mil minimum. |
|
Assembly | Two to 150 conductors, laid straight or irregular parallel in one plane. |
|
Shield | Optional. |
|
Covering | Optional - Polyester film, 0.02 - 4.0 mils bonded to cable with polyester adhesive. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits in electronic equipment. |
|