APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20706 Issued:1991-08-02
Revised:2017-12-07
Style 20706 Laminated flat ribbon cable.

Rating105 deg C, 60 Vac, Horizontal Flame.
Conductor42 AWG - 12 AWG, flat or round. If flat conductors, 1.0 - 10.0 mils thickness, 3 - 100 mils wide.
Insulation(1) PVC, 3.5 mils minimum bonded each side, or (2) 0.4 mil minimum biaxially oriented PETP film bonded each side with 0.5 mil polyester adhesive or (3) 0.8 mil minimum PETP film or flame retardant polyester film and 2.5 mils minimum PVC adhesive on each side of conductors laminated together. 10 mils minimum edge width and 3 mils minimum between conductors. (4) 0.4 mil minimum polyimide film bonded on each side of conductors with 0.4 mil minimum polyester adhesive. Total combined thickness shall be 0.8 mil minimum.
AssemblyTwo to 150 conductors, laid straight or irregular parallel in one plane.
ShieldOptional.
CoveringOptional - Polyester film, 0.02 - 4.0 mils bonded to cable with polyester adhesive.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024