Rating | 150 deg C, 600 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. The signations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermosplastic-tape wrap. |
|
Shield | Optional. |
|
Jacket | FEP, dia. o 0.425 inches or less, 12 mils min average, 10 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. |
|