APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20715 Issued:1991-09-04
Revised:2011-12-05
Style 20715 Multiple conductor cable using non-integral jacket.

Rating250 deg C, 600 Vac, Cable flame, Oil Resistant 80 deg C (optional).
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermosplastic-tape wrap.
ShieldOptional.
JacketBonded PTFE,TFE tape, dia. of 0.425 inches or less, 12 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: Suitable for immersion in oil at 80 deg C or 2500 V peak - For Electronic Use Only.

UL and the UL Logo are trademarks of UL LLC © 2024