APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2072 Issued:1959-05-01
Revised:2012-07-24
Style 2072 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor20 AWG - 16 AWG, stranded, consisting of 34 AWG strands.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyFour insulated conductors laid flat with overall jacket. Several different conductors sizes may be employed in one cable within specified size range. The jacket shall fill the valleys between adjacent conductors.
JacketExtruded PVC, 45 mils min average, 36 mils minimum at any point, and a nominal 30 mils wall compound along the sides of the cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor internal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024