APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2073 Issued:1959-05-01
Revised:2012-04-20
Style 2073 Multiple-conductor cable using non-interal jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor20 AWG - 16 AWG, Stranded, consisting of 34 AWG or smaller strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. Individual conductor insulations may be colored for circuit identification.
AssemblyFive conductors laid flat with overall jacket. The jacket shall fill the valleys between adjacent conductors. Adjacent conductors shall be separated into groups of not more than four each by 23 mils minimum interconnecting web extruded integral with jacket. May use same or mixed AWG sizes.
JacketExtruded PVC, 45 mils minimum average thickness, 36 mils minimum thickness at any point and a nominal 30 mils wall compound along the sides of the cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Television Remote Cable.

UL and the UL Logo are trademarks of UL LLC © 2024