APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20731 Issued:1992-02-03
Revised:2012-04-02
Style 20731 Laminated Flat Ribbon Cable

Rating80 deg C, 60 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationOne sheet - non-extruded Polyester, non-extruded XL Polyester, non-extruded PETP or non-extruded XLPETP, 0.4 mils minimum at any point, one sheet - non-extruded PVC or non-extruded XLPVC, 5 mils minimum at any point.
AssemblyTwo to 100 uninsulated conductors laid parallel in one plane, laminated between sheets. May include mixed AWG sizes. Minimum 5 mils between conductors, 5 mils minimum edge width.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.