Rating | 60 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG - 16 AWG, solid or stranded round. Different conductor sizes may be used in on cord. |
|
Insulation | Labeled and complying with manufacturer's AWM Procedure. See Facing Page for compound. Extruded polyester, 4.5 mils min average, 3.5 min at any point and 30 mils max. |
|
Assembly | Two to fifty insulated conductors. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Jacket | Extruded polyester. |
| major dia in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 in | 45 avg | 36 min |
| 1.001-1.500 in | 60 avg | 48 min |
| 1.501-2.500 in | 80 avg | 64 min |
| 2.501-4.000 in | 100 avg | 88 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of appliances or electronic equipment (such as computers and business machines). May be marked "-30 deg C" or "minus 30 deg C". |
|