APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20736 Issued:1992-04-17
Revised:2013-01-24
Style 20736 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 150 Vac, 300 V peak, Horizontal flame. Optional - -30 deg C.
Conductor40 AWG - 16 AWG, solid or stranded, tinned, bare or tinsel. May include mixed AWG sizes.
Insulated ConductorLabeled and complying with manufacturer's AWM Procedure, or Extruded Polyester insulation, 7 mils minimum thickness at any point, 30 mils maximum thickness.
AssemblyTwo to fifty insulated conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and or fillers optional.
ShieldOptional.
JacketExtruded Polyester, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or "Handset wire telephone cord for subscriber sets".