APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20737 Issued:1992-04-20
Revised:2011-11-21
Style 20737 Flat cable with extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 4 AWG, solid or stranded, round or flat, bare, silver plated or nickel plated copper. If flat, minimum width 20 mils, maximum width 2-1/2 inch, 1 mil minimum thickness, 15 mils maximum thickness.
InsulationOn each side of the conductor PET 2 mils minimum thickness at any point with PET adhesive, 1 mil minimum thickness at any point, backing bonded together. 25 mils minimum thickness at any point width on outside edges, 10 mils minimum thickness at any point width between adjacent conductors.
AssemblyTwo to 100 conductors. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.