APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20739 Issued:1992-05-15
Revised:2012-07-27
Style 20739 Jacketed cable.

Rating80 deg C, 300 Vac, Cable flame.
Conductor30 AWG - 16 AWG, solid or stranded copper.
InsulationPE, 13 mils min average, 11 mils minimum at any point.
AssemblyTwo insulated conductors may be twisted or parallel with covering, optional shield and jacket.
ShieldOptional.
Covering10 mils minimum at any point of Polyethylene covering extruded over the conductor assembly.
JacketPVC, 25 mils minimum average, 20 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA. "External interconnection of electronic equipment where the overall length does not exceed 5 ft". B. "External interconnection of electronic equipment where not routed along walls, floors, or other abuse areas".

UL and the UL Logo are trademarks of UL LLC © 2024