APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20740 Issued:1992-05-06
Revised:2012-05-29
Style 20740 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 300 Vac, Cable Flame.
Conductor24 AWG - 7 AWG, Solid or Stranded Round.
InsulationExtruded PVC
AWG conductor sizemils minimum averagemils minimum at any point
24-101816
9-73027
Optional. A conductive coating maybe applied between the conductor and the insulation. Thickness and material not specified.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG size.
ShieldInner and outer shield are optional.
CoveringOptional. Extruded PVC, 10 mil minimum at any point may be extruded over the conductor assembly.
JacketExtruded PVC
diameter in inchesmils minimum averagemils minimum at any point
0.700 or less3023
0.701-1.0004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Interconnection of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024