Rating | 60, 90 deg C, 600 Vac, Horizontal flame, Moisture Resistant 60 deg. C. |
|
Conductor | Resistance Wire. Nickel, Copper Alloy or Copper, size varies - dependent upon wattage demand. |
|
Insulation | Extruded PVC, 30 mils min average, 27 mils minimum at any point. R/C QMTT2 rated for type TW, THW or THWN compound, for 60 deg. C Wet, also suitable for use at 90 deg. C in air. |
|
Assembly | Consists of two conductors described above laid flat with an overall shield and jacket. |
|
Shield | Copper braid consisting of bare copper. Combination of strand size and number of strands such that braid is equivalent to 18 AWG. |
|
Covering | Optional. Extruded nylon, thickness 3 mils, plus or minus 1 mil. |
|
Jacket | Extruded PVC, 20 mils min average, 16 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. (Optional marking) The conductor alloy designation shall be included Ohms per foot rating. |
|
Use | Thermoplastic Insulated Resistance Wire for Heating Cable Units. The conductor alloy designation shall be included Ohms per foot rating (Optional marking). |
|