Rating | 60 deg C, 600 Vac, FT-2 flame. |
|
Conductor | 14 AWG - 10 AWG, solid or stranded. |
|
Insulation | Extruded PVC. 31 mils minimum average thickness, 28 mils minimum thickness at any point. PVC compound suitable for use on type TW wire. |
|
Covering | Extruded nylon. 3 mils minimum average thickness over insulation. |
|
Assembly | Consists of two insulated conductors described above laid flat with an overall shield and jacket. |
|
Shield | Copper braid consists of bare copper. Combination of strand size and number of strands such that braid is equivalent to 16 AWG. |
|
Jacket | Extruded PVC. 20 mils minimum average thickness, 16 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Only as factory assembled nonheating leads on deicing units for use in concrete or asphalt driveway, walk, etc. |
|