Rating | 105 deg C, 30 Vac, 150 Vac, 300 Vac, 600 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Inner - (optional) Extruded polybutylene terephthalate, PTFE or FEP, ETFE, PVC or PFA 2 mils min at any point, or PETP with a PVC or polyester adhesive (milene) or combination thereof, min wall at any point 2 mils or 0.5 mils min polyester terephthalate tape with optional PVC adhesive. Outer Covering - Conductive PFA with a minimum thickness of 5 mils employed over the cable core. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment or appliances. Conductive outer covering - remove covering before terminating or splicing. |
|