Rating | 60 deg C, 60 Vac, Cable flame. |
|
Conductor | 40 AWG minimum - Material not specified. |
|
Insulation | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form. |
|
Shield | Optional. |
|
Jacket | PUR |
| di. in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.00 in | 40 avg | 36 min |
| 1.001-1.500 in | 60 avg | 48 min |
| 1.501-2.50 in | 80 avg | 64 min |
| 2.501-4.00 in | 110 avg | 88 min |
| 4.001 in and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As internal wiring or external interconnection of electronic equipment (such as computers and electric business machines). |
|