APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20753 Issued:1992-08-20
Revised:2012-04-26
Style 20753 Multiple Conductor with Extruded Insulation

Rating200 deg C, 600 Vac, Horizontal flame.
ConductorResistance Wire, solid or stranded, 24 AWG min.
InsulationExtruded PFA, 22 mils minimum average thickness, 20 mils minimum thickness at any point.
AssemblyThree conductors with inner covering, insulation, optional middle covering and optional outer covering.
CoveringInner -Braided Glass. Middle - (optional)Braid and/or shield. Outer - (optional)18 mils min avg, 15 mils min at any point wall of extruded fluorinated ethylene propylene FEP.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024