APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20755 Issued:1992-08-20
Revised:2012-02-15
Style 20755 Heating Cable.

Rating200 deg C, 600 Vac, Horizontal flame.
ConductorResistance Wire, solid or stranded, 24 AWG minimum.
InsulationExtruded FEP, 22 mils minimum average thickness, 20 mils minimum thickness at any point.
AssemblyTwo or three conductors with inner covering, insulation, optional middle covering and optional outer covering.
CoveringExtruded, inner - Braided Glass. Middle - (optional) Braid and/or shield. Outer - (optional) 18 mils mininum average thickness, 15 mils minimum thickness at any point of extruded fluorinated ethylene propylene FEP.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024