APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20756 Issued:1992-08-20
Revised:2012-04-02
Style 20756 Multiple-Conductor cable using non-integral Extruded Insulation

Rating250 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG minimum, Resistance Wire, solid or stranded.
CoveringOptional. Braided Glass.
InsulationExtruded MFA or extruded PFA, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
AssemblyTwo conductors.
CoveringOptional. Braid and/or shield.
CoveringOptional. Extruded PFA or extruded MFA, 18 mils minimum average thickness, 15 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating Cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.