Rating | 250 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 24 AWG minimum, Resistance Wire, solid or stranded. |
|
Covering | Optional. Braided Glass. |
|
Insulation | Extruded MFA or extruded PFA, 20 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
Assembly | Two conductors. |
|
Covering | Optional. Braid and/or shield. |
|
Covering | Optional. Extruded PFA or extruded MFA, 18 mils minimum average thickness, 15 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Heating Cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|