APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2076 Issued:1959-05-01
Revised:2011-08-04
Style 2076 Multiple-Conductor with Extruded Insulation and Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorNo. 20-16 consisting of No. 34 AWG strands
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point
AssemblyEight conductors laid flat. Several different conductors sizes may be employed in one cable within this size range. The jacket shall fill the valleys between adjacent conductors. Adjacent conductors shall be separated into groups of not more than four each by 23 mils minimum web extruded integral with jacket.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Television Remote Cable where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024