APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20762 Issued:1992-10-09
Revised:2012-05-02
Style 20762 Flat ribbon cable

Rating125 deg C, 150, 300 Vac, Horizontal flame.
Conductor40-24 AWG, solid or stranded.
InsulationExtruded TPE, 5 mils minimum average thickness. Top or bottom layers may form ridges over conductors. See Facing Page for Compound.
Assembly2 - 150 conductors laid parallel.
ShieldOptional.
CoveringOptional. Extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electrical Equipment; such as Electronic Computers and Electric Business Machines.

UL and the UL Logo are trademarks of UL LLC © 2025