APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20768 Issued:1992-11-30
Revised:2012-01-25
Style 20768 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded, coated or bare copper or copper alloy.
InsulationExtruded FEP, 5 mils minimum average thickness, 4 mils minimum at any point. Coaxial Member Extruded FEP, 20 mils average thickness, 18 mils minimum thickness at any point, braided shield. Extruded PVC covering, 8 mils minimum average thickness, 6 mils minimum at any point.
AssemblyTwo or more insulated singles or coaxial members and fillers in any combination may be twisted together to form flat, oval, or round cable. Lay not specified.
ShieldOptional.
CoveringOptional. Fluropolymer Tape.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024