APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2077 Issued:1959-05-01
Revised:2011-08-04
Style 2077 Parallel Cable with Extruded Integral Insulation and Jacket

Rating80 deg C, 300 Vac, Horizontal flame
ConductorNo. 20-16 AWG consisting of No. 34 AWG copper strands
InsulationPVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point
AssemblyNine conductors laid flat. Several different conductors sizes may be employed in one cable within this size range. The jacket shall fill the valleys between adjacent conductors. Adjacent conductors shall be separated into groups of not more than four each by 23 mil minimum web extruded integral with jacket.
JacketPVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. The jacket shall fill the valleys between adjacent conductors. Adjacent conductors shall be separated into groups of not more than four each by 23 mil minimum web extruded integral with jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseFor use as Television Remote Cable where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024