APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20773 Issued:1992-12-23
Revised:2012-05-29
Style 20773 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Cable Flame.
InsulationLabeled or complying with manufacturer's AWM Conductors.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. May be coiled in the form of a helix. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier Extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
major diameter in inchesmils minimum averagemils minimum at any point
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External Interconnection of electronic equipment.