Rating | 60, 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 50 AWG min material and stranding not specified. |
|
Insulation | Extruded solid or foamed PP, 2 mils min average. May be irradiated. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. Manufacturer shall maintain a complete description of each assembly. Insulated conductor with optional inner shield, optional inner covering, optional middle covering, optional outer shield and optional outer covering. |
|
Shield | Inner and outer shield are optional. |
|
Covering | Inner - Optional. Extruded PVC, 2 mils min at any point. Middle - Extruded PVC, Polyamide, Polyester or Lacquered braid. Outer - Extruded PVC, 2 mils min average, 1.8 mils min at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For Internal Wiring of Class 2 circuits in electronic equipment or, external patch cord for use between units in rack mounted equipment/component systems in Class 2 circuits only. |
|