APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20778 Issued:1993-02-10
Revised:2019-11-07
Style 20778 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 600 Vac, Cable flame.
Conductor14 AWG - 2000 kcmil solid or stranded round, tinned or bare copper.
InsulationFRPE
14-2 AWG conductor size60 mils min average54 mils minimum at any point
1-4/0 AWG80 avg72 min
250-500 kcmils95 avg86 min
550-1000 kcmils110 avg99 min
1100-2000 kcmils125 avg112 min
AssemblyTwo or more insulated conductors, twisted pairs or groups of twisted singles twisted together to form a round or oval cable. The lay of the conductors are not specified. Cable may employ optional fillers and may use the same or mixed conductor sizes.
ShieldOptional.
CoveringOptional. PVC; extruded over the conductor assembly.
JacketPE
dia in inches
0.425 o less45 mils min average36 mils minimum at any point
0.426-0.700 in60 avg48 min
0.701-1.500 in80 avg64 min
1.501-2.500 in110 avg88 min
2.500 in and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024