APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20779 Issued:1993-03-04
Revised:2019-11-07
Style 20779 Multiple conductor cable using non-integral jacket.

Rating105 deg C, 600 Vac, Oil Resistant 60 or 80 deg C, Moisture Resistant 75 deg C
InsulationLabeled or complies with manufacturer's AWM Singles.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain complete description of each assembly. May use mixed sizes of insulated singles.
ShieldOptional.
JacketExtruded PVC
dia in inches
0.425 or less45 mils min average36 mils minimum at any point
0.426-0.70 in60 avg48 min
0.701-1.500 in80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment where exposed to temperatures not exceeding 105 deg C in dry location 75 deg C in wet location, 60 deg C or 80 deg C (whichever is applicable) in oil.

UL and the UL Logo are trademarks of UL LLC © 2024