APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2078 Issued:1959-05-01
Revised:2019-10-11
Style 2078 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorExtruded PE insulated Coax Cable- No. 26 AWG, extruded PVC insulated Conductors - 20 AWG (26 strands of 34 AWG), No. 18 AWG (41 strandsof 34 AWG), No. 24 AWG(16 strands of 36 AWG).
InsulationExtruded PVC insulation on all conductors except coaxial cable conductor, PVC to be 30 mils minimum average thickness, 27 mils minimum thickness at any point. On Coaxial cable conductor, insulation shall be extruded Thermoplastic PE, 38 mils minimum average thickness, 34 mils minimum thickness at any point.
AssemblyEleven conductors. One - 73 ohm miniature coaxial cable (No. 26 AWG copper-clad steel) Three - No. 20 AWG (26 strands
34 AWG copper) Two - No. 18 AWG (41 strands
34 AWG copper) Five - No. 24 AWG(16 strands #36 AWG copper) See Facing Page for Arrangement of Conductors. Coaxial conductor in center and the other ten wrapped around it with a lay of 4 to 6 inches. Fillers as required to round out cable. Coaxial cable insulation shall be Thermoplastic (Polyethylene), provided with a shield over insulation consisting of a copper braid using No. 36 AWG strands, and jacketed with PVC.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Remote Control Cable on Television Receivers.