Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 2-150, 40-12 AWG flat conductor, 0.8 - 10.0 mils thick, 10-100 mils wide. Straight or irregular parallel in one plane. |
|
Insulation | On each side of the conductors, 0.5 mils minimum of non-extruded irradiated flame retardant polyolefin adhesive bonded to 0.8 mils minimum of non-extruded PETP film. Minimum 10 mils insulation width on outside edges of conductors and 10 mils minimum insulation width between adjacent conductors. |
|
Assembly | Two to 150 conductors. Length of insulated conductors not specified. |
|
Shield | Optional. |
|
Covering | Optional. Non-extruded PETP film, 0.02 - 4.0 mils bonded to cable with polyester adhesive. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|