APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20786 Issued:1993-04-09
Revised:2012-04-26
Style 20786 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 600 Vac, FT2 flame.
Conductor0.75 sq mm - 25 sq mm, solid or stranded.
InsulationExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
0.75-1.0 sq mm30 mils27 mils
1.01-6.0 sq mm45 mils40 mils
6.01-25.0 sq mm60 mils54 mils
AssemblyTwo or more conductors, same as type ST, May use same or mixed AWG size.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.500 inch or less80 mils64 mils
0.501-0.750 inch95 mils76 mils
0.751-1.000 inch110 mils88 mils
1.001-1.500 inch125 mils100 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024