Rating | 60, 75 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG - 10 AWG. Material not specified. |
|
Insulation | Extruded PP, solid or cellular, 5 mils minimum average thickness, 100 mils maximum thickness. |
|
Assembly | Two to 150 insulated conductors with optional inner covering, optional shield, optional outer covering and jacket. |
|
Shield | Optional, expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh construction. |
|
Covering | Extruded inner and outer covering are optional. PVC, 2 mils minimum average thickness or polyester film 0.5 mils minimum average thickness. |
|
Jacket | Extruded PVC |
| dia in inches |
| 2.500 or less | four or more cables | 30 mils min average | 24 mils min at any point |
| 2.501-3.500 dia | four or more cables | 45 avg | 36 min |
| dia in inches of 3.501 or less | three or less cables | 30 avg | 24 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Interconnection of Electronic Equipment in Class 2 or 3 Circuits Only. |
|