Rating | 105 deg C, 30 Vac, Cable flame for Construction A, Horizontal flame for Construction B. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Two or more conductors, twisted pairs of groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. A 6 mil thick or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | Extruded PVC. |
| | Construction A External Use | | Construction B Internal Use | |
| Diameter of cable under jacket | Minimum average thickness in mils | Minimum thickness at any point in mils | Minimum average thickness in mils | Minimum thickness at any point in mils |
| 0.350 inch or less | 20 | 17 | 15 | 12 |
| 0.351-0.700 inch | 30 | 24 | 30 | 24 |
| 0.701-1.000 inch | 40 | 36 | 40 | 36 |
| 1.001-1.500 inch | 54 | 48 | 54 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only. |
|