APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20792 Issued:1993-05-12
Revised:2012-01-04
Style 20792 Parallel cable with extruded integral insulation and jacket

Rating60, 75, 80, 90, 105 deg C, No voltage specified, FT2 flame, sunlight resistant.
ConductorTwo or three, No. 18 AWG - 8 AWG. Each consisting seven or more tinned or bare copper strands
InsulationIntegral with Jacket, similar to type SPT-3 flexible cord (outdoor). PVC
18-14 AWG conductor size45 mils min average40 mils minimum at any point54 mils min web
12 AWG60 avg54 min72 min web
10-8 AWG80 avg72 min72 min web
See Facing Page for compound designation, or shall use any of the Recognized Component (QMTT2) 720 h Sunlight-Resistant PVC insulation and jacket compounds.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLow voltage outdoor application in lighting fixtures, or low voltage lighting cable.