APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2080 Issued:1959-05-01
Revised:2011-12-02
Style 2080 Parallel cable with extruded integral insulation

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorNo. 18 or 16 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point. The following minimum (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in..
Assemblytwo conductors, same as type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of butter conditioners where exposed at the the door hinge at a temperature not exceeding 105 deg C or internal wiring of electric refrigerators where ripped not more than three inches. Polarity identificatin may be omitted.