APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20802 Issued:1993-08-12
Revised:2019-11-07
Style 20802 Multiple-conductor cable using non-integral jacket,

Rating90 deg C, 600 Vac, Cable flame.
Conductor40 AWG min, solid or stranded.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded TPU - See Facing Page for Compound.
dia in inches
0.700 or less60 mils min average48 mils min at any point
0.701-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection of electronic equipment (such as computers and business machines).

UL and the UL Logo are trademarks of UL LLC © 2024