| Rating | 105 deg C, 600 Vac, Cable flame. |
|
| Conductor | 40 AWG minimum. |
|
| Insulation | Labeled or complying with manufacturer's AWM Procedure having a minimum rating of 105 deg C, 600 Volts. |
|
| Assembly | Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional. |
|
| Covering | Optional. a 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded PVC. |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.500 inch | 80 mils | 64 mils |
| *Major diameter if cable is flat or oval |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | External interconnection or internal wiring of electronic equipment. |
|