APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20813 Issued:1993-10-13
Revised:2012-04-02
Style 20813 Multiple-conductor cable using non-integral jacket

Rating150, 200 deg C, 300 Vac, Horizontal flame, Optional - 80 deg C Oil, Optional - Gasoline Resistant
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationExtruded FEP, 10 mils min average, 8 mils minimum at any point.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors described above, cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly or individual conductors or groups of conductors.
JacketExtruded FEP, 20 mils min average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where the jacket is exposed to sulfuric acid in concentrations not exceeding 10 N.