APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20814 Issued:1993-10-20
Revised:2019-11-07
Style 20814 Multiple conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG min solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC
major dia in inches
0.350 or less15 mils min average12 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and appliances. Tags may indicate the following: "30 volts Peak for Electronic use only".