APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20815 Issued:1993-11-24
Revised:2012-04-13
Style 20815 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 90 Vac, Cable flame.
InsulationLabeled or complies with this Manufacturer's AWM procedure.
AssemblyTwo or more conductors, insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional - Extruded PVC, 5mils minimum thickness, extruded PTFE, extruded PFA, extruded FEP or extruded ETFE, 5 mils minimum thickness at any point. PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal and external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024