APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2082
Issued:
1959-05-01
Revised:
2011-10-27
Style
2082
SPT-3 Cord
Rating
105 deg C, 300 Vac, Horizontal flame.
Conductor
No. 14, 12 or 10 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
Insulation
Integral with Jacket. PVC, 80 mils min average, 72 mils minimum at any point. the following minimum (pin gauge) dimensions: Wall thickness 0.070 in., Web thickness 0.109 in., Wall after rip: 0.043 in..
Assembly
Two conductors, same as type SPT-3.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of room cooler units where ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C. Polarity identification may be omitted.
UL and the UL Logo are trademarks of UL LLC © 2024