APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2082 Issued:1959-05-01
Revised:2011-10-27
Style 2082 SPT-3 Cord

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorNo. 14, 12 or 10 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 80 mils min average, 72 mils minimum at any point. the following minimum (pin gauge) dimensions: Wall thickness 0.070 in., Web thickness 0.109 in., Wall after rip: 0.043 in..
AssemblyTwo conductors, same as type SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C. Polarity identification may be omitted.
 
UL and the UL Logo are trademarks of UL LLC © 2024