APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20822 Issued:1994-02-03
Revised:2019-11-07
Style 20822 Multiconductor Cable with Extruded Non-integral Jacket.

Rating105 deg C, 30 Vac, Cable flame.
Conductor40 AWG - 10 AWG solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The flat cable may consist of 2 or more groups of conductors with the jacket forming an interconnecting web. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded EPDM (EPTR - Ethylene Propylene Thermoplastic Rubber)
major dia in inches
0.700 or less30 mils min average24 mils min at any point
0.701-1.000 dia45 avg36 min
1.001-1.501 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment or internal wiring of electronic equipment or appliances.