Rating | 105 deg C, 150 Vac, Cable flame. |
|
Conductor | 40 AWG - 10 AWG solid or stranded |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The flat cable may consist of 2 or more groups of conductors with the jacket forming an interconnecting web. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. A 6 mil thick or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | Extruded EPDM |
| Major Diameter of Cable in inches | Average minimum thickness in mils | Minimum thickness at any point in mils |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.501 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. |
|