Rating | 105 deg C, 300 Vac, Cable flame. |
|
Conductor | 40 AWG - 10 AWG solid or stranded round, tinned or bare copper. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The flat cable may consist of 2 or more groups of conductors with the jacket forming an interconnecting web. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional - Extruded PVC, 6 mils minimum thickness at any point. |
|
Jacket | Extruded EP |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701 - 1.000 inch | 45 mils | 36 mils |
| 1.001 - 1.501 inches | 60 mils | 48 mils |
| * - Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. |
|