Rating | 105 deg C, 300 Vac, Cable flame. |
|
Conductor | 40 AWG mimimum, solid or stranded. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductor or groups of singles may be laid parallel forming a flat, oval or round cable. The flat cable may consist of 2 or more groups of conductors with the jacket forming an interconnecting wed. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional - Extruded PVC, 6 mils minimum thickness, may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded EPTR. |
| @Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 45 mils | 36 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.501 inch | 80 mils | 64 mils |
| @ - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|