APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20826 Issued:1994-03-24
Revised:2019-11-07
Style 20826 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal flame, Oil Resistant 80 deg C.
Conductor40 AWG - 10 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with AWM Maunfacture's Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
CoveringOptional.
JacketPVC
dia in inches
0.248 or less20 mils min average16 mils minimum at any point
0.249-0.425 dia30 avg24 min
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or internal wiring of appliances where jacket exposed to oil at a temperature not exceeding 80 deg. C.

UL and the UL Logo are trademarks of UL LLC © 2024