Rating | 105 deg C, 300 Vac, Horizontal flame, Oil Resistant 80 deg C. |
|
Conductor | 40 AWG - 10 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with AWM Maunfacture's Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Covering | Optional. |
|
Jacket | PVC |
| dia in inches |
| 0.248 or less | 20 mils min average | 16 mils minimum at any point |
| 0.249-0.425 dia | 30 avg | 24 min |
| 0.426-0.700 dia | 45 avg | 36 min |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.001-1.500 dia | 80 avg | 64 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or internal wiring of appliances where jacket exposed to oil at a temperature not exceeding 80 deg. C. |
|