Rating | 80 deg C, 30 Vac, Horizontal flame, constructions 1A, 1B, Cable flame, constructions 2A, 2B. |
|
Conductor | 40 AWG min. Material not specified. |
|
Insulation | Labeled or complies with manufacturer's AWM Procedure for use statement 2A or 2B. Material not specified - For use Statement 1A, 1B. |
|
Assembly | Consists of two or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. Extruded PVC, 5 mils min thickness at any point, over the assembly or groups of singles. |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded PVC |
| Dia of cable under jacket* | Minimum average | Minimum at any point |
| 0.250 inch or less | 15 mils | 12 mils |
| 0.251-0.424 inch | 30 mils | 27 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 inch or larger | 140 mils | 112 mils |
| * Major dia if flat or oval construction |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Use No. 1A Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.
Use No. 1B Cables using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.
Use No. 2A Internal wiring in class 2 circuits of electronic equipment or external interconnection in class 2 circuits of electronic equipment wherenot routing along walls, floors, or other abuse areas. or
Use No. 2B Cables using 30 mils or greater jacket thickness only: External interconnection or internal wiring in class 2 circuits of electronic equipment. |
|