APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2083 Issued:1959-05-01
Revised:2008-05-27
Style 2083 SPT-3 Cord.

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorNo. 14, 12 or 10 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 80 mils min average, 72 mils minimum at any point.
AssemblyThree conductors, same as type SPT-3 except for a nominal 80 mil wall minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.109 in., Wall after rip: 0.043 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units when ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C. Polarity identification may be omitted.
 
UL and the UL Logo are trademarks of UL LLC © 2024