Rating | 80 deg C, 150 Vac, 600 Vac, Cable flame, construction A; Horizontal flame, Construction B. |
|
Conductor | 50 AWG - 10 AWG, solid or stranded. |
|
Insulation | Labeled AWM Styles 2576 and 2463. |
|
Assembly | AWM Styles 2576 and 2463 joined together by an interconnecting web. |
|
Jacket | Extruded PVC. |
| major dia. in inches |
| 0.350 or less | (Const. A) | 30 mils minimum average thickness | 24 mils minimum thickness at any point |
| major dia. in inches of 0.350 or less | (Const. B) | 20 mils minimum average thickness | 17 mils minimum thickness at any point |
| 0.351-0.700 dia | (Const. A) & (Const. B) | 30 avg | 24 min |
| 0.701-1.000 dia | (Const. A) & (Const. B) | 40 avg | 36 min |
| 0.1001-1.500 dia | (Const. A) & (Const. B) | 54 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal or external wiring. Construction B: Internal wiring. |
|